NORDTEK DANMARK - Toroid Transformer 230V, 2xSec, 15VA - nordtek.com

Toroid Transformer 230V, 2xSec, 15VA


High quality open style 15VA toroidal transformers with a single 230V a.c. 50/60Hz primary winding.
Twin secondary windings may be connected in series, parallel or used independently.

  Toroid Transformer 230V, 2xSec, 15VA   Schematic - Electrical   Primary: 230V @ 50/60Hz

Secondary: 2 x Vsec @ 7.5VA Each
Suitable for Series/Parallel connection
  Open wound totoidal transformer  


Part Number Full Load Vsec (V) Rated Current
per Sec (A)
No Load Vsec (V) DC Resistance (Ohms)
@ 25°C
0015P1-2-006 2x6 1.250 2x7.02 2x0.4789
0015P1-2-009 2x9 0.833 2x10.42 2x1.0092
0015P1-2-012 2x12 0.625 2x13.89 2x1.6850
0015P1-2-015 2x15 0.500 2x17.29 2x2.6122
0015P1-2-018 2x18 0.417 2x20.92 2x4.0612


Primary Winding

Input Voltage Range: 230V ± 10% (207V - 253V) @ 50/60Hz
DC Resistance @ 25°C = Approx 153 Ohms
Magnetising Current @ 230V = Approx 2.6mA
Magnetising Current @ 253V = Approx 14.0mA

Losses

Iron Losses 0.2 Watts approx
Copper Losses 2.6 Watts approx

Temperature Class

Winding Wire (Primary & Secondary) - Class H (180°C)
Insulation between input and output - Class B (130°C)
Connection lead insulation - Class A (105°C)

Standards

Approved to UL506: File E215495
Approved to EN61558: KEMA Certificate 2001469
Conforms to EN60065, VDE0550, BS415.

Physical Data

Approximate Dimensions:
Diameter 60mm - Measured away from lead-out bulge; Allow extra 4mm at leads.
Height 31 mm

Approximate Weight:
0.30 Kg

Terminations

Primary:
UL 1569 Flexible leads, 150mm Long with 10mm stripped ends, double-insulated over entire length with Class A PVC tubing.

Secondary:
Solid copper conductors (extension of winding wire), insulated over their entire length with PVC tubing. 150mm Long, 10mm tinned ends.


Mounting Hardware:

Each transformer is supplied with a mounting kit, comprising: 2 pieces of Neoprene Insulating discs, 1 piece of Dished Steel Washer.



See other power variants here: 230V, 2xSec, 15-1000VA