    AS Series Current Sensors - HF 20-200kHz
    AS Series Current Sensors are designed as a low cost method of controlling, monitoring or measuring AC currents. The sensors serve as feedback elements between the output and pulse control circuitry providing accurate regulation of switch mode power supplies. 
 
AS-100 Series 
AS-200/300 Series 
AS-400 Series 
 
    
        
            
            Features
            
                - Fully encapsulated for optimal PC board mounting
 
                - Frequency range from 20kHz to 200kHz
 
                - Primary current rating to 15 Amps
 
                - Primary to secondary isolated to 2500 VAC
 
                - UL 94-V0 recognized materials
 
                - Optimum performance over designated current and frequency range
 
                - Competitive pricing due to high volume production
 
                - Manufactured in ISO-9000 approved facility
 
             
             | 
              | 
              | 
         
    
 
Applications
Isolated current feedback signal in Switch Mode Power Supplies - Motor current load/overload - Lighting Switch Controls Ultra-sound current - High resolution sonar current - Isolated bi-directional current sensor with full wave bridge rectifier. 
 
 
 AS-100 Series
Electrical Specifications at 25°C
 
    
        
            | Inductor Part Number | 
            Prim/Sec Ratio | 
            Lsec (1) 
            (mH Min) | 
            DCRsec Ohms (Max) | 
            Sec Term (2) Resistance Ohms (Nom.) | 
            Isec (3) Max | 
            Vols-µS (4) Max | 
            Schematic | 
         
        
             AS-100 
             AS-101 
             AS-102 
             AS-103 
             AS-104 
             AS-105 | 
            1/50 
            1/100 
            1/200 
            1/300 
            1/500 
            1/750 | 
            6 
            25 
            100 
            250 
            700 
            1,682 | 
            0.6 
            1.1 
            4.5 
            10.0 
            25.0 
            43.0 | 
            50 
            100 
            200 
            300 
            500 
            750 | 
            300mA 
            150mA 
            75mA 
            50mA 
            30mA 
            40mA | 
            175 
            350 
            700 
            900 
            1,500 
            3,750 | 
              | 
         
        
             AS-110 
             AS-111 
             AS-112 
             AS-113 
             AS-114 
             AS-115 | 
            1/50CT 
            1/100CT 
            1/200CT 
            1/300CT 
            1/500CT 
            1/750CT | 
            6 
            25 
            100 
            250 
            700 
            1,682 | 
            0.3/0.3 
            0.55/0.55 
            2.25/2.25 
            5.0/5.0 
            12.5/12.5 
            21.5/21.5 | 
            25+25 
            50+50 
            100+100 
            150+150 
            250+250 
            375+375 | 
            300mA 
            150mA 
            75mA 
            50mA 
            30mA 
            40mA | 
            175 
            350 
            700 
            900 
            1,500 
            3,750 | 
              | 
         
    
 
 
 
    
        
            Notes: 
             
            1) Lsec: Secondary inductance tested at 10kHz and 10mV for 1:50 through 1:500. 
            Prim./Sec. ratios and 1kHz/10mV for Prim./Sec. ratio of 1:750 
             
            2) This nominal termination resistance value will yield approximately 1.0V of output for each amp of current in a single turn sense line. The output Voltage/Ampere of these devices can be increased or decreased linearly over a restricted temperature range by adjusting the terminating resistance. 
             
            3) For Prim./Sec. Ratios of 1:50 through 1:500, the Isec value corresponds to a maximum primary current of 15 Amp-turns rms while the Isec values for the ratio of 1:750 corresponds to a max. primary current of 30 Amp-turns rms 
             
            4) VµS = Rt x ls x (1/2F) 
             
            Rt (Ohms): Recommended Terminating Resistance 
            Is (A): Secondary Current 
            F (Hz): Frequency 
             
            5) Operating Temperature Range: -40°C to +120°C 
             
            6) Pin 2 is on Centre-Tapped (CT) versions only | 
              | 
              | 
         
    
 
 
#top# 
 
 
 
 AS-200/300 Series
Electrical Specifications at 25°
 
    
        
            | Type 1 | 
            Type 2 | 
            Prim./Sec. 
            Ratio | 
            Lsec (1) 
            (mH Min.) | 
            DCRsec 
            Ohms (Max) | 
            Sec. Term (2) 
            Resistance 
            Ohms (Nom.) | 
            Isec (3) 
            Max. | 
            Volt-µS (4) 
            Max. | 
            Schedule | 
         
        
             AS-200 
             AS-201 
             AS-202 | 
             AS-300 
             AS-301 
             AS-302 | 
            1/50 
            1/100 
            1/200 | 
            5 
            20 
            80 | 
            0.65 
            1.30 
            4.50 | 
            50 
            100 
            200 | 
            300mA 
            150mA 
            75mA | 
            175 
            350 
            700 | 
              | 
         
        
             AS-210 
             AS-211 
             AS-212 | 
             AS-310 
             AS-311 
             AS-312 | 
            1/50 
            1/100 
            1/200 | 
            5 
            20 
            80 | 
            0.65 
            1.30 
            4.50 | 
            25+25 
            50+50 
            100+100 | 
            300mA 
            150mA 
            75mA | 
            175 
            350 
            700 | 
              | 
         
        
            |   | 
             AS-320 
             AS-321 
             AS-322 | 
            1/50 
            1/100 
            1/200 | 
            5 
            20 
            80 | 
            0.65 
            1.30 
            4.50 | 
            50 
            100 
            200 | 
            300mA 
            150mA 
            75mA | 
            175 
            350 
            700 | 
              | 
         
        
            |   | 
             AS-330 
             AS-331 
             AS-332 | 
            1/50CT 
            1/100CT 
            1/200CT | 
            5 
            20 
            80 | 
            0.65 
            1.30 
            4.50 | 
            25+25 
            50+50 
            100+100 | 
            300mA 
            150mA 
            75mA | 
            175 
            350 
            700 | 
              | 
         
    
 
 
 
#top# 
 
 
 
 
 AS-400 Series
Features:
    - Meets requirements of IEC 950 and VDE norms
 
    - UL 94-V0 recognized materials
 
    - Operating frequency range from 20 kHz to 200 kHz
 
    - Operating Temperature Range: -40 °C to +120 °C
 
    - Primary to secondary isolated to 4000 VAC
 
    - Primary current rating to 80 Amps
 
 
 
Electrical Specifications at 25°C 
 
 
    
        
            Part 
            Number | 
            Prim./Sec 
            Ratio | 
            Ip A | 
            Volt-µS 
            (4) 
            Max. | 
            Application | 
            Schedule | 
            Box Type | 
            Dimensions | 
         
        
            | C | 
            D | 
            E | 
            F | 
            G | 
            H | 
            I | 
            Hole | 
         
        
             AS-400 
             AS-401 
             AS-402 | 
            1/100 
            1/100 
            1/100 | 
            1 
            2 
            5 | 
            350 
            550 
            1,500 | 
            Switching 
            Switching 
            Switching | 
              | 
            A 
            A 
            B | 
            17.8 
            23.0 
            32.5 | 
            12.8 
            15.5 
            18.0 | 
            20.0 
            25.0 
            35.5 | 
            10.0 
            12.5 
            15.0 | 
            5.0 
            10.0 
            12.5 | 
            15.0 
            20.0 
            - | 
            5.0 
            5.0 
            -  | 
            - 
            - 
            - | 
         
        
            |  AS-403 | 
            1/100 | 
            10 | 
            1,500 | 
            Switching | 
              | 
            A | 
            32.5 | 
            18.0 | 
            35.5 | 
            15.0 | 
            12.5 | 
            - | 
            - | 
            - | 
         
        
             AS-404 
             AS-405 
             AS-406 
             AS-407 | 
            1/100 
            1/500 
            1/500 
            1/500 | 
            50 
            50 
            65 
            80 | 
            1,500 
            2,700 
            4,200 
            7.500 | 
            Switching 
            Switching 
            Switching 
            Switching | 
              | 
            B 
            A 
            A 
            B | 
            32.5 
            23.0 
            27.0 
            32.5 | 
            18.0 
            15.5 
            18.0 
            18.0 | 
            35.5 
            25.0 
            30.0 
            35.5 | 
            15.0 
            12.5 
            15.0 
            15.0 | 
            12.5 
            10.0 
            12.5 
            12.5 | 
            - 
            20.0 
            22.5 
            - | 
            - 
            5.0 
            5.0 
            - | 
            Ø 8 
            Ø 6 
            Ø 8 
            Ø 8 | 
         
    
 
 
 
 
 
#top#
     
    | 
  
  
   
    
    
     Nordtek Denmark - current sensor, ei30, ee20, pcb transformer, vergossen, plug in transformer, topswitch, simple switcher
Nordtek Com - transformer design, magnetics, impedance, transformer ac, toroids
strommessung, netztrafo, power supply,voltage transformer, telecom transformer, pulse
current sense transformer, drossel, current sense transformer, inductive, ferrite, kleintransformatoren
inductor, inductance, 3c85, 3f3, power transformer, toroid, 50/60hz, line transformer, emi
talema chokes, talema toroid, nuvotem transformer, talema current transformers, talema current sensors, talema mini transformers, talema cross reference
electronic starter, flicker starter, fluorescent lamps, safety starter, lamp starter, glow starters, tubestarter, rapid, ts8, sunbed, halogen transformer
     
    |