Home / Products / Telecom & Network / ISDN Transformer & Transformer Module / S Interface - ISDN S Interface Single Transformers / ISJ -Mini Interface Transformer
ISJ -Mini Interface Transformer
| The ISJ Series ISDN Miniature Interface Transformers are designed for optimum compatibility with all established interface IC's. They comply fully with CCITT.I.430 recommendations and have an operating temperature from 0° to +70°C. | ![]() |
Product information and technical data
Features
|
![]() |
|
| Electrical Specifications @ 25°C | Standard Packaging: Tape and Reel |
Surface Mount SO Interface Transformers
| Part Number | LN (mH Min.) |
Turns Ratio |
LL (µH Max.) |
CC (pF Max.) |
RCUP (Ohms) |
RCUS (Ohms) |
VP (Vrms) |
| ISJ-100B | 25 | 1:1 | 2.0 | 60 | 3.8 | 3.8 | 1,500 |
| ISJ-140B | 25 | 1:2 | 2.0 | 50 | 4 | 8 | 1,500 |
| Test Conditions | ||
| Inductance (Lo): | Line Side Windings in series - measurement @ 10kHz, 100mV | |
| Polarity and Turns Ratio: | Pins 1-2:3-4:5-6:7-8=±2% | |
| Coupling Capacitance: | IC side winding (windings in series) to Line side windings in series @ 10kHz, 100mV | |
| Leakage Inductance: | Line side windings in series, IC side windings short circuited - measurement @ 100kHz, 100mV | |
| Test Voltage: | 1.5kV for 2 Sec. - Line side windings in series to IC side windings in series | |
| Coplanarity: | ±0.004(0.10mm) |
Dimensions

#top#