Electrical Specifications @ 25°C |
|
Turns Ratio: Bold = IC side windings |
Surface Mount SO Interface Transformers
Part Number |
LP
(mH Min.) |
Turns
Ratio |
LL
(µH) |
^IDC
(mA) |
CC
(pF Max.) |
RCUP
(Ohms) |
RCUS
(Ohms) |
VP
(Vrms) |
Schematic |
SMJ & SWJ SMD Series comply with Basic Insulation Level EN60950, UL1950 and UL1450 |
SMJ-100B
SMJ-130B
SMJ-140B |
30
30
30 |
1:1:1:1
1:1:2.5:2.5
1:1:2:2 |
5
5
5 |
4
4
4 |
100
100
100 |
1.65
1.65
1.65 |
1.7
4.4
3.4 |
1,500
1,500
1,500 |
B
B
B |
SWJ-100B
SWJ-130B
SWJ-140B |
30
30
30 |
1/1:1/1
1/1:2.5/2.5
1/1:2/2 |
10
10
10 |
5
5
5 |
150
150
150 |
1.7
1.7
1.7 |
2.0
4.6
4.0 |
1,500
1,500
1,500 |
B
B
B |
SHJ Series Interface Transformers comply with Reinforced Insulation Level EN60950 and UL1950 ** |
SHJ-200B
SHJ-220A |
30
30 |
1:1:1:1
1:1:4 |
10
10 |
5
5 |
45
45 |
1.7
1.7 |
1.9
3.7 |
3,000
3,000 |
B
A |
SHJ-230B
SHJ-240B |
30
30 |
1:1:2.5:2.5
1:1:2:2 |
10
10 |
5
5 |
45
45 |
1.7
1.7 |
4.7
3.7 |
3,000
3,000 |
B
B |
** SOTransformer modules comply with Reinforced Insulation Level EN60950:1992/A4: 1997, para. 2.9.4.4 when tested in accordance with 6.4.1
Test Conditions: |
|
Standard Packaging:Tape and Reel |
Inductance and coupling capcitance: 10kHz, 100mV |
|
|
Leakage Inductance: 100kHz, 100mV |
|
|
|
|
|
Package Style & Schematics
Surface Coplanarity will be 0.004(0.10)
Dimensions: Inches (Millimeters)
Tolerance: ±0.010 (0.25) unless specified otherwise
|
Nordtek Denmark - current sensor, ei30, ee20, pcb transformer, vergossen, plug in transformer, topswitch, simple switcher
Nordtek Com - transformer design, magnetics, impedance, transformer ac, toroids
strommessung, netztrafo, power supply,voltage transformer, telecom transformer, pulse
current sense transformer, drossel, current sense transformer, inductive, ferrite, kleintransformatoren
inductor, inductance, 3c85, 3f3, power transformer, toroid, 50/60hz, line transformer, emi
talema chokes, talema toroid, nuvotem transformer, talema current transformers, talema current sensors, talema mini transformers, talema cross reference
electronic starter, flicker starter, fluorescent lamps, safety starter, lamp starter, glow starters, tubestarter, rapid, ts8, sunbed, halogen transformer
|